Description
5000 Watts 48V TBB RiiO Sun Hybrid Solar Inverter Charger
5000 Watts 48V TBB Hybrid Solar Inverter Charger can be used for a generator hybrid system. With the innovative function of Power Control and Power Assist, it can be used to work with a generator or a limited AC source. Kinergier Pro can automatically adjust its charging current avoiding the generator or grid to be overloaded. In case of high power, requirement appeared it can work as a supplement source to a generator or grid. As the result, it could dramatically improve fuel efficiency and decrease the size of the generator as well.
5000 Watts 48V TBB RiiO Sun Hybrid Solar Inverter Charger Specs
All in one, plug-and-play design for easy installation
Applicable for DC coupling systems, solar hybrid systems, and power backup system
The generator power assist function enables small generators to handle big loads
Save 45% energy at max under the built-in ECO Mode (30% on average)
Load boost function for running the heavy duty loads
Extremely high inverter efficiency of up to 94%
Extremely high MPPT efficiency of up to 98%
Harmonic distortion<2%
Extremely low self-consumption power
High performance designed for all kinds of inductive loads
TBB premium II battery charging management
Built-in battery SOC estimation
Equalization charging program available for flooded and OPZS battery
Lithium battery charging is available and fully programmable by the APP
Remote monitoring and control via NOVA online portal
Product Description
Product Parameters
Model
|
RiiO 2KVA-M
|
RiiO 3KVA-M
|
RiiO 2KVA-S
|
RiiO 3KVA-S
|
RiiO 4KVA-S
|
RiiO 5KVA-S
|
RiiO 6KVA-S
|
Product Topology
|
Transformer based
|
||||||
Generator Power Assist
|
Yes
|
||||||
AC input voltage range(VAC)
|
175~265
|
||||||
AC input Frequency range(Hz)
|
45~65
|
||||||
AC input Current (transfer switch) (A)
|
32
|
50
|
|||||
Inverter
|
|||||||
Nominal battery voltage (V)
|
24
|
48
|
|||||
Input voltage range (V)
|
21-34
|
42-68
|
|||||
AC output voltage(VAC)
|
220/230/240 ± 2%
|
||||||
AC output Frequency(Hz)
|
50/60 ± 0.1%
|
||||||
Harmonic distortion
|
<2%
|
||||||
Load Power factor
|
1
|
||||||
Cont. output power at 25°C (VA)
|
2000
|
3000
|
2000
|
3000
|
4000
|
5000
|
6000
|
Max Output Power at 25°C (W)
|
2000
|
3000
|
2000
|
3000
|
4000
|
5000
|
6000
|
Peak power (3sec) (W)
|
4000
|
6000
|
4000
|
6000
|
8000
|
10000
|
12000
|
Surge
|
300%
|
||||||
Maximum efficiency
|
91%
|
91%
|
93%
|
93%
|
93%
|
94%
|
94%
|
Zero load power (W)
|
13
|
17
|
13
|
17
|
19
|
22
|
25
|
Charger
|
|||||||
Charge voltage ‘absorption’ (V)
|
28.8
|
57.6
|
|||||
Charge voltage ‘float’ (V)
|
27.6
|
55.2
|
|||||
Battery types
|
AGM / GEL / OPZV / Lead-Carbon / Li-ion / Flooded/Traction/TBB SUPER-L
|
||||||
Max AC charge current (A)
|
40
|
70
|
20
|
35
|
50
|
60
|
70
|
Temperature compensation
|
YES
|
||||||
General data
|
|||||||
Output (AC Out) Current (A)
|
32
|
50
|
|||||
Transfer time
|
4ms (<15ms in Weak AC source Mode)
|
||||||
Protection
|
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) input voltage out of range
g) input voltage ripple too high
h) Fan block
|
||||||
General purpose com. Port
|
RS485 (GPRS, WLAN optional with Kinergy)
|
||||||
Operating temperature range
|
-20˚C to 65˚C
|
||||||
Relative humidity in operation
|
95% without condensation
|
||||||
Altitude (m)
|
2000
|
||||||
Standards
|
|||||||
Safety
|
EN-IEC 62477-1
|
||||||
EMC
|
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-3-11,EN61000-3-12
|
Reviews