1/2/3 KVA Delta N Series Online Tower Smart UPS

  ... people are viewing this right now
Compare

KSh 35,000.00 Ex-VAT

+

1/2/3 KVA Delta N Series Online Tower Smart-UPS

The Amplon N Series UPS is a true online, double-conversion 1kva UPS, 2kva UPS, or 3kva UPS housed in a compact tower. Double-conversion UPS systems are lighter in weight than other types of UPSs and can regulate output frequency from 50 to 60 hertz.

The power-factor correction functions of such systems enable them to draw current from an AC line as smooth sine waves, instead of as pulses.

It features significant advantages, including an output power factor of 0.9 and up to 93% AC-AC efficiency for greater energy savings.

Double-conversion UPS systems use less battery power and draw current from the battery without interruption.

Built-in batteries provide critical loads with continuous and stable power in the event of a power interruption. Users enjoy nearly ideal electrical output performance and superior power quality.

The Amplon N Series is designed to eliminate disturbances to workstations, POSs, ATMs or home appliances.

For longer backup time requirements you can add an external battery pack to enhance availability for critical applications.

Technical Specifications

Model: N-1K / N-2K / N-3K

Power Rating:

  • N-1K1 kVA / 0.9 kW
  • N-2K2 kVA / 1.8 kW
  • N-3K3 kVA / 2.7 kW

Input

Nominal Voltage: 220/230/240 Vac

Voltage Range: 175~280 Vac (full load), 80~175 Vac (50-100% load)

Frequency: 50/60 Hz ± 10 Hz

Power Factor: > 0.99 (full load)

Current Harmonic Distortion: < 3%

Output

Power Factor: 0.9

Voltage: 220/230/240 Vac

Frequency: 50/60 Hz ± 0.05 Hz

Voltage Harmonic Distortion: < 3% (linear load)

Overload Capability: < 105%: Continuous

105~125%: 1 minute

125~150%: 30 seconds

Crest Factor: 3:1

Receptacle:

  • N-1KIEC C13 x 4
  • N-2K/3KIEC C13 x 6, C19 x 1

Efficiency

AC-AC:

  • N-1K91%
  • N-2K/3KUp to 93%

Battery

Battery Voltage:

  • N-1K24 Vdc
  • N-2K48 Vdc
  • N-3K72 Vdc

Typical Backup Time: 4.5 min.(full load), 13 min.(half load)

Recharge Time: 3 hrs to 90%

Charge Current: 1.5 A

Audible Noise:

  • N-1K< 43 dBA
  • N-2K/3K< 48 dBA

Display: LCD panel

Interface: MINI Slot x 1, USB Port x 1

Conformance

Safety & EMCCE/RCM/EN62040-1/EN62040-2 Category C2

Physical

Dimensions (W x D x H):

  • N-1K145 x 320 x 225 mm
  • N-2K/3K190 x 390 x 325 mm

Weight:

  • N-1K9 kg
  • N-2K18.6 kg
  • N-3K24.4 kg

Environment

Operating Temperature: 0~40ºC

Relative Humidity: 5~95% (non-condensing)

User Guide Manual

Based on 0 reviews

0.00 Overall
0%
0%
0%
0%
0%
Be the first to review “1/2/3 KVA Delta N Series Online Tower Smart UPS”

Your email address will not be published. Required fields are marked *

Write a review

Reviews

There are no reviews yet.

Category:
Close My Cart
Close Recently Viewed
Close
Close
Categories